NON-PRESSURE SPIGOT PIPE (TS TYPE)

  • Product Options:

    Our products are equipped with high-strength rubber O-rings from German companies CORDES GmbH and Dichtungstechnik GmbH (DS), which officially guarantee the service life of their products for 80 to 100 years. These O-rings have significant advantages in ensuring the tightness of the pipeline in the butt joints.

  • Application:

    Reinforced concrete pipes are used in the construction of embankments, dams, highways, railroad tracks. They are used in civil and industrial engineering, when laying water supply and sanitation systems (sewerage, wastewater, stormwater, sanitary wastewater, amelioration), in the construction of hydraulic structures and for pumping liquids under pressure and by gravity.

  • For your information:

    According to GOST, in territories with seismicity of 7 and 8 points, only pipes joined using rubber O-rings can be used. Sapa Su pipes are equipped with rubber O-rings and, thanks to an increase in pipe wall thickness of up to 50 mm, they withstand seismicity of up to 9 points.

№ п/п

Name of

reinforced concrete pipe

with lining

Product code in case of pipe calculation in running metres AEPB RK 8.04-08-2021

Inner

Ø

(mm)

Outer

Ø

(mm)

Wall

thickness

(mm)

Useful

length

(mm)

 

Product mass

(t)

 

Bearing capacity (height of backfilling)

1

TS 30.25-3 (4,5)

241-702-0201

300

410

55

2500

0,47

up to 6-8-10 metres

2

TS 40.25-3 (4,5)

241-702-0202

400

520

60

2500

0,66

up to 6-8-10 metres

3

TS 50.25-3 (4,5)

241-702-0204

500

630

65

2500

0,84

up to 6-8-10 metres

4

TS 60.25-3 (4,5)

241-702-0205

600

740

70

2500

1,12

up to 6-8-10 metres

5

TS 80.25-3 (4,5)

241-702-0206

800

970

85

2500

1,8

up to 6-8-10 metres

6

TS 100.25-3 (4,5)

241-702-0207

1000

1210

105

2500

2,8

up to 6-8-10 metres

7

TS 120.25-3 (4,5)

241-702-0208

1200

1430

115

2500

3,5

up to 6-8-10 metres

8

TS 140.25-3 (4,5)

241-702-0210

1400

1660

130

2500

4,5

up to 6-8-10 metres

9

TS 160.25-3 (4,5)

241-702-0211

1600

1880

140

2500

5,2

up to 6-8-10 metres

10

TS 180.25-3 (4,5)

241-702-0212

1800

2120

160

2500

6,44

up to 6-8-10 metres

11

TS 200.25-3 (4,5)

241-702-0213

2000

2340

170

2500

7,8

up to 6-8-10 metres

12

TS 220.25-3 (4,5)

241-702-0214

2200

*

*

2500

*

up to 6-8-10 metres

13

TS 240.25-3 (4,5)

241-702-0215

2400

*

*

2500

*

up to 6-8-10 metres

 


The tile under the non-pressure pipe is an idea of Sapa Su LLP; it is used in water-saturated soils as foundation support and is placed under the body of a non-pressure pipe. It is made of heavy weight concrete B30 (M400), with water-resistance of W6, frost-resistance of F300, seismic resistance of 9 points.


Advantages of using the reinforced-concrete non-pressure spigot pipes:

Non-pressure reinforced concrete spigot pipes with round openings are made of heavy weight concrete and are designed for laying underground pipelines that by gravity transport wastewater and household fluids, as well as industrial fluids and groundwater, non-aggressive to reinforced concrete.

TS is the type of bell-mouthed cylindrical pipes with butting stepped surfaces of spigot pipe end, as well as a butt joint sealed with rubber O-rings.

Reinforced-concrete non-pressure pipes of TS type are produced in accordance with applicable GOST 6482-2011, series 3.820-7

Such reinforced-concrete pipes are divided into five categories by bearing capacity:

1st: if calculated soil backfill height is 2 metres;

2nd: if calculated soil backfill height is 4 metres;

3rd: if calculated soil backfill height is 6 metres;

4th: if calculated soil backfill height is 8 metres;

5th: if calculated soil backfill height is 10 metres;

Name

Inner D (mm)

Outer D 1 (mm)

Wall thickness S (mm)

Useful length L (mm)

Product weight (t)

TS 30.25-3

300

410

55

2500

0.48

TS 40.25-3

400

520

60

2500

0.58

TS 50.25-3

500

640

70

2500

0.95

TS 60.25-3

600

750

75

2500

1.2

TS 80.25-3

800

1000

100

2500

1.95

TS 100.25-3

1000

1240

120

2500

2.9

TS 125.25-3

1250

1530

140

2500

4.2

TS 140.25-3

1400

1710

155

2500

5.33

TS 160.25-3

1600

1940

170

2500

6.13

TS 180.25-3

1800

2200

200

2500

7.95

TS 200.25-3

2000

2400

200

2500

8.83

TS 220.25-3

2200

2600

200

2500

9.7

TS 240.25-3

2400

2800

210

2500

10.6


Delivery

Calculation of pipe size for a railway wagon

d 300

d 400

d 500

d 600

d 800

d 1000

d 1250

d 1400

d 1600

d 1800

d 2000

0.48t

0.58t

0.95t

1.2t

1.95t

2.9t

4.15t

5.33t

6.13t

7.95t

8.6t

60 pcs.

50 pcs.

45 pcs.

39 pcs.

20 pcs.

16 pcs.

7 pcs.

6 pcs.

6 pcs.

6 pcs.

5 pcs.

Calculation of pipe size for motor transport (53’ trailer, carrying capacity is 20 tons)

d 300

d 400

d 500

d 600

d 800

d 1000

d 1250

d 1400

d 1600

d 1800

d 2000

0.48t

0.58t

0.95t

1.2t

1.95t

2.9t

4.15t

5.33t

6.13t

7.95t

8.6t

15 pcs.

15 pcs.

10 pcs.

10 pcs.

8 pcs.

4 pcs.

4 pcs.

3 pcs.

2 pcs.

2 pcs.

2 pcs.



OUR PRODUCTS