№ п/п |
Name of reinforced concrete pipe with lining |
Product code in case of pipe calculation in running metres AEPB RK 8.04-08-2021 |
Inner Ø (mm) |
Outer Ø (mm) |
Wall thickness (mm) |
Useful length (mm) |
Product mass (t)
|
Bearing capacity (height of backfilling) |
1 |
TS 30.25-3 (4,5) |
241-702-0201 |
300 |
410 |
55 |
2500 |
0,47 |
up to 6-8-10 metres |
2 |
TS 40.25-3 (4,5) |
241-702-0202 |
400 |
520 |
60 |
2500 |
0,66 |
up to 6-8-10 metres |
3 |
TS 50.25-3 (4,5) |
241-702-0204 |
500 |
630 |
65 |
2500 |
0,84 |
up to 6-8-10 metres |
4 |
TS 60.25-3 (4,5) |
241-702-0205 |
600 |
740 |
70 |
2500 |
1,12 |
up to 6-8-10 metres |
5 |
TS 80.25-3 (4,5) |
241-702-0206 |
800 |
970 |
85 |
2500 |
1,8 |
up to 6-8-10 metres |
6 |
TS 100.25-3 (4,5) |
241-702-0207 |
1000 |
1210 |
105 |
2500 |
2,8 |
up to 6-8-10 metres |
7 |
TS 120.25-3 (4,5) |
241-702-0208 |
1200 |
1430 |
115 |
2500 |
3,5 |
up to 6-8-10 metres |
8 |
TS 140.25-3 (4,5) |
241-702-0210 |
1400 |
1660 |
130 |
2500 |
4,5 |
up to 6-8-10 metres |
9 |
TS 160.25-3 (4,5) |
241-702-0211 |
1600 |
1880 |
140 |
2500 |
5,2 |
up to 6-8-10 metres |
10 |
TS 180.25-3 (4,5) |
241-702-0212 |
1800 |
2120 |
160 |
2500 |
6,44 |
up to 6-8-10 metres |
11 |
TS 200.25-3 (4,5) |
241-702-0213 |
2000 |
2340 |
170 |
2500 |
7,8 |
up to 6-8-10 metres |
12 |
TS 220.25-3 (4,5) |
241-702-0214 |
2200 |
* |
* |
2500 |
* |
up to 6-8-10 metres |
13 |
TS 240.25-3 (4,5) |
241-702-0215 |
2400 |
* |
* |
2500 |
* |
up to 6-8-10 metres |
Advantages of using the reinforced-concrete non-pressure spigot pipes:
Non-pressure reinforced concrete spigot pipes with round openings are made of heavy weight concrete and are designed for laying underground pipelines that by gravity transport wastewater and household fluids, as well as industrial fluids and groundwater, non-aggressive to reinforced concrete.
TS is the type of bell-mouthed cylindrical pipes with butting stepped surfaces of spigot pipe end, as well as a butt joint sealed with rubber O-rings.
Reinforced-concrete non-pressure pipes of TS type are produced in accordance with applicable GOST 6482-2011, series 3.820-7
Such reinforced-concrete pipes are divided into five categories by bearing capacity:
1st: if calculated soil backfill height is 2 metres;
2nd: if calculated soil backfill height is 4 metres;
3rd: if calculated soil backfill height is 6 metres;
4th: if calculated soil backfill height is 8 metres;
5th: if calculated soil backfill height is 10 metres;
Name |
Inner D (mm) |
Outer D 1 (mm) |
Wall thickness S (mm) |
Useful length L (mm) |
Product weight (t) |
TS 30.25-3 |
300 |
410 |
55 |
2500 |
0.48 |
TS 40.25-3 |
400 |
520 |
60 |
2500 |
0.58 |
TS 50.25-3 |
500 |
640 |
70 |
2500 |
0.95 |
TS 60.25-3 |
600 |
750 |
75 |
2500 |
1.2 |
TS 80.25-3 |
800 |
1000 |
100 |
2500 |
1.95 |
TS 100.25-3 |
1000 |
1240 |
120 |
2500 |
2.9 |
TS 125.25-3 |
1250 |
1530 |
140 |
2500 |
4.2 |
TS 140.25-3 |
1400 |
1710 |
155 |
2500 |
5.33 |
TS 160.25-3 |
1600 |
1940 |
170 |
2500 |
6.13 |
TS 180.25-3 |
1800 |
2200 |
200 |
2500 |
7.95 |
TS 200.25-3 |
2000 |
2400 |
200 |
2500 |
8.83 |
TS 220.25-3 |
2200 |
2600 |
200 |
2500 |
9.7 |
TS 240.25-3 |
2400 |
2800 |
210 |
2500 |
10.6 |
Calculation of pipe size for a railway wagon
d 300 |
d 400 |
d 500 |
d 600 |
d 800 |
d 1000 |
d 1250 |
d 1400 |
d 1600 |
d 1800 |
d 2000 |
0.48t |
0.58t |
0.95t |
1.2t |
1.95t |
2.9t |
4.15t |
5.33t |
6.13t |
7.95t |
8.6t |
60 pcs. |
50 pcs. |
45 pcs. |
39 pcs. |
20 pcs. |
16 pcs. |
7 pcs. |
6 pcs. |
6 pcs. |
6 pcs. |
5 pcs. |
Calculation of pipe size for motor transport (53’ trailer, carrying capacity is 20 tons)
d 300 |
d 400 |
d 500 |
d 600 |
d 800 |
d 1000 |
d 1250 |
d 1400 |
d 1600 |
d 1800 |
d 2000 |
0.48t |
0.58t |
0.95t |
1.2t |
1.95t |
2.9t |
4.15t |
5.33t |
6.13t |
7.95t |
8.6t |
15 pcs. |
15 pcs. |
10 pcs. |
10 pcs. |
8 pcs. |
4 pcs. |
4 pcs. |
3 pcs. |
2 pcs. |
2 pcs. |
2 pcs. |